Verify Fan Module Functionality

1.
Verify that the Service Required LED on the replaced fan module is not lit.
See
"Fan Module LEDs" on page
2.
Verify that the Top Fan LED and the Service Required LED on the front of the
server are not lit.
See
"Front Panel Controls and LEDs" on page
If you are replacing a fan module when the server is powered down, the LEDs might
Note -
stay lit until power is restored to the server and the server can determine that the fan module is
functioning properly.
3.
Use the Oracle ILOM show faulty command to verify that the fault has been
cleared.
See
"Managing Faults" on page 46
4.
Perform one of the following tasks based on your verification results:
If the previous steps did not clear the fault, see
for information about the tools and methods you can use to diagnose component faults.
If the previous steps indicate that no faults have been detected, then the component has been
replaced successfully. No further action is required.