Servicing the Fan Board
This board carries power to the fan modules and fan module status LEDs. This board also
transmits status and control signals for the fan modules.
These topics describe how to service the fan board.
"Remove the Fan Board" on page 135
■
"Install the Fan Board" on page 137
■
"Verify Fan Board Functionality" on page 139
■
Remove the Fan Board
These procedures require that you handle components that are sensitive to ESD. This
Caution -
sensitivity can cause the component to fail. To avoid damage, ensure that you follow antistatic
practices as described in
This is a cold-service procedure that must be performed by qualified service personnel. The
server must be completely powered down before performing this procedure. See
Service Categories" on page 57
Prepare for servicing.
1.
a.
Attach an antistatic wrist strap.
b.
Power off the server and unplug power cords from the power supplies.
See
"Removing Power From the Server" on page
c.
Extend the server to the maintenance position.
See
"Extend the Server to the Service Position" on page
d.
Remove the top cover.
"ESD Measures" on page
for more information about this category of service procedures.
54.
58.