Configuring Post - Oracle SPARC T5-2 Service Manual

Hide thumbs Also See for SPARC T5-2:
Table of Contents

Advertisement

Configuring POST

No.
LED
(green on right)
5
Locator LED and button
(white)
6
Service Required LED
(amber)
7
Power OK LED
(green)
8
Host Ethernet Port Link/
Activity LED
(green)
These LEDs, from left to
right, represent NET 1, NET
0, NET 3, and NET 2.
Related Information
"Front Panel Controls and LEDs" on page 37
"Understanding Diagnostics" on page 31
Configuring POST
These topics explain how to configure POST as a diagnostic tool.
"POST Overview" on page 41
"Oracle ILOM Properties That Affect POST Behavior" on page 41
"Configure POST" on page 43
"Run POST With Maximum Testing" on page 45
40
SPARC T5-2 Server Service Manual • February 2017
Icon or Label
Description
■ Off – The link is operating as a 10-Mbps connection.
■ Steady On – The link is operating as a 100-Mbps connection.
Turn on the Locator LED by pressing the Locator button, or see
"Locate the Server" on page
The fmadm faulty command provides details about any faults that
cause this indicator to light. See
Under some fault conditions, individual component fault LEDs are lit
in addition to the Service Required LED.
Indicates these conditions:
■ Off – Server is not running in its normal state. System power might
be off. The SP might be running.
■ Steady on – Server is powered on and is running in its normal
operating state. No service actions are required.
■ Fast blink – Server is running in standby mode and can be quickly
returned to full function.
■ Slow blink – A normal but transitory activity is taking place. Slow
blinking might indicate that system diagnostics are running or that
the system is booting.
Indicates these conditions:
■ Off – No link is established.
■ Steady On – A link is established.
■ Blinking – A link is established and there is activity on the port.
57. When lit, the LED blinks rapidly.
"Check for Faults" on page
46.