Verify a Fan Module

1.
Verify that the Service Required LED on the replaced fan module is not lit.
See
"Fan Module LEDs" on page
2.
Verify that the Top Fan LED and the Service Required LED on the front of the
server are not lit.
See
"Front Panel Controls and LEDs" on page
If you are replacing a fan module when the server is powered down, the LEDs might
Note -
stay lit until power is restored to the server and the server can determine that the fan module is
functioning properly.
3.
Use the Oracle ILOM show faulty command to verify that the fault has been
cleared.
See
"Identify Faulted Components" on page 24
command.
Consider these two possibilities.
If the previous steps did not clear the fault, see
Faults" on page 23
to diagnose component faults.
If the previous steps indicate that no faults have been detected, then the
component has been replaced successfully. No further action is required.
Related Information
"Determine Which Fan Module Is Faulty" on page 75
"Front Panel Components (Service)" on page 13
"Rear Panel Components (Service)" on page 15