Configuring POST
Parameter
/HOST/diag trigger
/HOST/diag verbosity
This flowchart illustrates the same set of Oracle ILOM set command variables.
42
SPARC T5-2 Server Service Manual • February 2017
Values
min
none
hw-change
hw_change_level
hw_change_verbosity
power-on-reset
power_on_level
power_on_verbosity
error-reset
error_reset_level
error_reset_verbosity
all-resets
normal
min
max
debug
none
Description
If diag mode=normal, runs minimum set of tests.
Does not run POST on reset.
(Default) Runs POST following a FRU replacement or an AC
power cycle.
■ max (default) – Runs the maximum set of tests.
■ min – Runs the minimum set of tests.
■ min (default) – Displays the minimum level of output.
■ max – Displays information for each step.
■ normal – Displays a moderate amount of information,
including component names and test results.
■ debug – Displays extensive debugging information.
■ none – Disables the output.
Runs POST on every power on.
■ max (default) – Runs the maximum set of tests.
■ min – Runs the minimum set of tests.
■ min (default) – Displays the minimum level of output.
■ max – Displays information for each step.
■ normal – Displays a moderate amount of information,
including component names and test results.
■ debug – Displays extensive debugging information.
■ none – Disables the output.
(Default) Runs POST if fatal errors are detected.
■ max (default) – Runs the maximum set of tests.
■ min – Runs a minimum set of tests.
■ min (default) – Displays the minimum level of output.
■ max – Displays information for each step.
■ normal – Displays a moderate amount of information,
including component names and test results.
■ debug – Displays extensive debugging information.
■ none – Disables the output.
Runs POST after any reset.
Displays all test and informational messages in POST output.
Displays functional tests with a banner and pinwheel in POST
output.
Displays all test, informational, and some debugging
messages in POST output.
Displays extensive debugging information.
Does not display POST output.