Hardware Known Issues
■
■
■
■
■
■
■
■
■
System Might Shut Down Due to a Fan Module Failure
Bug ID 15725346
After some fan module failures, you can replace the fan module without shutting down the
server. However, once you remove the failed fan module, you must insert the replacement fan
module within 60 seconds. Otherwise the system shuts down with a fan column fail fault.
Other more severe fan module failures cause the system to automatically shut down and register
a fan column fail fault, which occurs when both fans in a counter-rotating pair go below a
minimum speed.
fault.chassis.device.fan.column-fail
Affected Hardware:
Sun Fire X4170 M2 Server
■
Sun Fire X4270 M2 Server
■
If the system shuts down due to a fan column fail fault, you must clear the fault before you can
restart the system.
Sun Fire X4170 M2 and X4270 M2 Servers Product Notes
Known Issues
21