Installing Standard 11-Pin Box Type Vehicle Detectors - HySecurity StrongArm 14F Programming And Operations Manual

Vehicular barrier gate operator with controller
Table of Contents

Advertisement

i
s
nstallinG
If standard 11-pin box type vehicle detectors are to be used, perform the following procedure.
If there is sufficient space, install the sockets in the control box; if not, then install them in a separate external
housing. Carefully consider your peripheral connections. Any peripheral device required for safe gate
operation should be attached to 24VDC in case of an AC power outage.
NOTE: Box detectors with relays require five times more power than Hy5A detectors. One Hy5A detector draws about 0.005A.
Consider Hy5A vehicle detectors for DC and Solar powered sites.
1. Connect 24 Volt power to the detector. Connect Pin No. 1 to a 24VAC or 24VDC terminal and Pin No. 2
to common.
2. Connect output Pin No. 6 to the Common Bus and output Pin No. 5 to one of the four detector
terminal inputs (depending upon the detector function required) on the Smart Touch Controller.
If multiple detectors are used, route the power
wires and common wire from socket to socket
(daisy-chaining) rather than individually running
each wire to the same location. The only wires
that are separate are the output wire to the
Smart Touch Controller and the detector loop
input wires.
Always keep the detector loop wires well
twisted beyond the area of the loop. The
lead in portion sealed in a saw cut does not
need to be twisted so long as the wires are
encapsulated in loop sealant and cannot move.
MX3657-01 Rev. D ©2020
11-P
tandard
Vehicle Detector Installation
B
t
in
ox
yPe
Inputs
Box Detector
Loop Detector
VEHICLE LOOP
Common
To LOOP terminal on Smart Touch Controller
hysecurity.com | 800-321-9947
V
d
ehiCle
eteCtors
DRIVE
POWER
1
STOP BUTTON
2
OPEN BUTTON
3
CLOSE BUTTON
REMOTE OPEN AND
4
RADIO CONTROL
5
OPEN/CLOSE
6
OPEN PARTIAL
INTERLOCK OPEN
7
TIME CLOCK OPEN
8
FREE EXIT DETECTOR
DISABLE EXIT DETECTOR
9
DISABLE CLOSE TIMER
10
INSIDE OBSTRUCTION
VEHICLE DETECTOR
OUTSIDE OBSTRUCTION
11
VEHICLE DETECTOR
12
SHADOW/RESET
VEHICLE DETECTOR
SENSOR 1
14
SENSOR
COM
15
16
DO NOT USE
17
SENSOR 2
18
DO NOT USE
19
SENSOR 3
20
DO NOT USE
CHARGER
21
AC LOSS
22
LOCK INTERLOCK
23
EMERG CLOSE
24
FIRE DEPT OPEN
Smart Touch Controller
LED
LIMIT
DUAL GATE
RPM
COM
A
B
COM
RS485
COM
NO
STATUS
HySecurity
MX000585
VERSION
S/N
RADIO OPTIONS
S 1
OPEN
+24V
+24V
COM