4. Controller SP Mode Tables
5-816-002 CE Call
5-816-003 Function Flag
5-816-007 SSL Disable
5-816-008 RCG Connect Timeout
5-816-009 RCG Write Timeout
5-816-010 RCG Read Timeout
5-816-011 Port 80 Enable
5-816-013 RFU Timing
5-816-014 RCG Error Cause
5-816-021 RCG – C Registed
5-816-023 connect type(N/M)
5-816-061 Cert Expire Timing
528
*CTL
[0 or 1 / 0 / 1]
0: Start of the service
1: End of the service
*CTL
[0 or 1 / 0 / 1]
0: Disabled
1: Enabled
*CTL
[0 or 1 / 0 / 1]
0: Yes. SSL not used.
1: No. SSL used.
*CTL
[1 to 90 / 30 / 1second/step]
*CTL
[0 to 100 / 60 / 1second/step]
*CTL
[0 to 100 / 60 / 1second/step]
*CTL
[0 or 1 / 0 / 1]
0: No. Access denied
1: Yes. Access granted.
*CTL
[0 or 1 / 1 / 1]
0: Any status of a target machine
1: Sleep or panel off mode only
CTL
[0 or 1 / 0 / 1]
0: Initial state, normal condition
1: Error
*CTL
[0 or 1 / 0 / 1]
0: Installation not completed
1: Installation completed
*CTL
[0 or 1 / 0 / 1]
0: internet connection
1: Dial-up connection
*CTL
[0 to 0xffffffff / 0 / 1]
0: Not use
1: Use