3. Engine SP Mode Tables
5-803-032 Toner Collection Full Sensor
Detects full of waste toner bottle.
(0: Not full, 1: full)
5-803-033 Toner Collection Bottle Set
Sensor
Detects that waste toner bottle is set to main unit.
(0: set, 1:not set)
5-803-034 Toner End Sensor:Y
Detects remaining toner amount.
*Power with SP5-804-173 before checking.
(0: End, 1: Not End)
5-803-035 Toner End Sensor:M
Detects remaining toner amount.
*Power with SP5-804-173 before checking.
(0: End, 1: Not End)
5-803-036 Toner End Sensor:C
Detects remaining toner amount.
*Power with SP5-804-173 before checking.
(0: End, 1: Not End)
454
ENG
[0 or 1 / 0 / 1/step]
0: Not full
1: full
ENG
[0 or 1 / 0 / 1/step]
0: set
1: not set
ENG
[0 or 1 / 0 / 1/step]
0: End
1: Not End
ENG
[0 or 1 / 0 / 1/step]
0: End
1: Not End
ENG
[0 or 1 / 0 / 1/step]
0: End
1: Not End