3. Engine SP Mode Tables
5-804-175 Drum PCL: FC
5804
5-804-176 PP: Charge DC: Y
5-804-177 PP: Charge DC: M
5-804-178 PP: Charge DC: C
5-804-179 PP: Charge DC: K
5-804-180 PP: Charge AC: Y
5-804-181 PP: Charge AC: M
5-804-182 PP: Charge AC: C
5-804-183 PP: Charge AC: K
5804
5-804-184 PP: Development: Y
5-804-185 PP: Development: M
5-804-186 PP: Development: C
5-804-187 PP: Development: K
5804
484
Lights (PWM drive) the drum PCL (FC).
* Continuing the OPC's exposure, it might accumulate damage due to electrostatic
locally.
• If operating QL without rotation, be sure to stop it within 10 seconds.
• Do rotate the OPC drum when QL is turned on.
[OUTPUT Check]
Outputs PWM for electrify HVP (DC/AC:Y/M/C/K).
[OUTPUT Check]
Outputs PWM for develop HVP.
[OUTPUT Check]
Outputs PWM for transfer HVP (image transfer: Y/M/C/K).