3. Engine SP Mode Tables
5-803-065 Fusing Motor: Lock
Detects locking of fusing motor.
(0: Running, 1: Stopped, or locked)
5-803-066 Transfer Drum Motor K: Lock
Detects locking of transfer drum motor K.
(0: Running, 1: Stopped, or locked)
5-803-068 PP:CB:SC Detection
Detects SC of HVP (electrify/develop).
(0: SC detected, 1: Normal)
5-803-069 PP:TTS:SC Detection
Detects SC of HVP (transfer).
(0: SC detected, 1: Normal)
5-803-072 Key Counter: Set 1
Detects setting of key counter.
(0: set, 1:unset)
(key counter: set 1=0, 2=1 for set, others for unset)
458
ENG
[0 or 1 / 0 / 1/step]
0: Stopped, or locked
1: Running
ENG
[0 or 1 / 0 / 1/step]
0: Stopped, or locked
1: Running
ENG
[0 or 1 / 0 / 1/step]
0: SC detected
1: Normal
ENG
[0 or 1 / 0 / 1/step]
0: SC detected
1: Normal
ENG
[0 or 1 / 0 / 1/step]
0: set
1:unset