Parameter
MWI Display
enable-mwi
[MWIDisplay]
Subscribe to MWI
subscribe-to-mwi
[EnableMWISubscriptio
n]
MWI Server IP Address
mwi-srvr-ip-addr
[MWIServerIP]
MWI Server Transport
Type
mwi-srvr-transp-
type
[MWIServerTransportTy
pe]
MWI Subscribe
Expiration Time
mwi-subs-expr-
time
[MWIExpirationTime]
MWI Subscribe Retry
Time
mwi-subs-rtry-
time
[SubscribeRetryTime]
Subscription Mode
subscription-mode
[SubscriptionMode]
etsi-vmwi-type-
one-standard
[ETSIVMWITypeOneSt
andard]
Version 7.0
Enables sending MWI information to the phone display.
[0] Disable = (Default) MWI information isn't sent to display.
[1] Enable = The device generates an MWI message (determined by
the parameter CallerIDType), which is displayed on the MWI display.
Note:
The parameter is applicable only to FXS interfaces.
The parameter can also be configured in a Tel Profile.
Enables subscription to an MWI server.
[0] No (default)
[1] Yes
Notes:
To configure the MWI server address, use the MWIServerIP
parameter.
To configure whether the device subscribes per endpoint or per the
entire device, use the parameter SubscriptionMode.
Defines the MWI server's IP address. If provided, the device subscribes to
this IP address. The MWI server address can be configured as a
numerical IP address or as a domain name. If not configured, the Proxy
IP address is used instead.
Determines the transport layer used for outgoing SIP dialogs initiated by
the device to the MWI server.
[-1] Not Configured (default)
[0] UDP
[1] TCP
[2] TLS
Note: When set to 'Not Configured', the value of the parameter
SIPTransportType is used.
Defines the MWI subscription expiration time in seconds.
The default is 7200 seconds. The range is 10 to 2,000,000.
Defines the subscription retry time (in seconds) after last subscription
failure.
The default is 120 seconds. The range is 10 to 2,000,000.
Determines the method the device uses to subscribe to an MWI server.
[0] Per Endpoint = (Default) Each endpoint subscribes separately -
typically used for FXS interfaces.
[1] Per Gateway = Single subscription for the entire device - typically
used for FXO interfaces.
Determines the ETSI Visual Message Waiting Indication (VMWI) Type 1
sub-standard.
[0] = (Default) ETSI VMWI between rings
[1] = ETSI VMWI before ring DT_AS
1009
59. Configuration Parameters Reference
Description
Mediant 1000B Gateway and E- SBC

Advertisement

Table of Contents
loading

Table of Contents