Mode Menu; Crossloading Fixtures - High End Systems studio spot User Manual

Automated projection and effect luminaire
Hide thumbs Also See for studio spot:
Table of Contents

Advertisement

Mode Menu

Use the following subsection to perform the functions contained within
the M O d E menu.

Crossloading Fixtures

Studio Spot can crossload software from one fixture to additional Studio
Spot fixtures on the same link (32 fixtures per link). To crossload software,
complete the following procedure:
1. Disconnect the data cable between the controller and the first fixture.
2. Hold <
MENU
software version) until the display changes to A d d R .
3. Using the up and down buttons, scroll to the M O d E field and press
<
>.
ENTER
4. Using the up and down buttons, scroll to the X L d field and press
<
>. The master fixture will upload its software to all
ENTER
connected fixtures on the link. The slave fixtures will display U P L d
during the process. After the fixtures have completed the upload, they
will reset and home.
Notes: if the fixture(s) take longer than one minute to reset after an upload,
turn off the fixture(s) and repeat the procedure. If a new boot code
was included with the latest software, you will need to store the boot
code on each fixture. Refer to "Changing Boot Codes" on page 3-20.
> on the master fixture (the fixture with the latest
Chapter 3 Menu System 3-25