Calibrating Pan

Pan position is easily calibrated to a precise preset position. Pan can be
adjusted in 0.4° increments for up to 8.0°. To calibrate pan, complete the
following procedure:
1. Hold <
MENU
2. Using the up and down buttons, scroll to the S E T field and press
<
>.
ENTER
3. Using the up and down buttons, scroll to the P C A L field and press
<
>.
ENTER
4. Using the up and down buttons, set the pan calibration from
(- 0 2 0 to + 0 2 0 ) and press <
5. Check the calibration by homing the fixture. Repeat the procedure as
necessary.

Calibrating Tilt

Tilt position is easily calibrated for precise preset positions. Tilt can be
adjusted in 0.4° increments up to 8.0°. To calibrate tilt, complete the
following procedure:
1. Hold <
MENU
2. Using the up and down buttons, scroll down to the S E T field and
press <
ENTER
3. Using the up and down buttons, scroll to the T C A L field and press
<
>.
ENTER
4. Using the up and down buttons, set the tilt calibration from (- 0 2 0 to
+ 0 2 0 ) and press <
5. Check the calibration by homing the fixture. Repeat the procedure as
necessary.

Preset Menu

The preset menu (P R S T ) allows you to program and playback scenes
from Studio Spot's on-board memory. This information is covered in detail
in Chapter 4 Preset Scenes.
> until the display changes to A d d R .
ENTER
> until the display changes to A d d R .
>.
>.
ENTER
>.