General Troubleshooting

Use the following table to troubleshoot problems that are not identified by the
menu system.
Problem
Unit will not turn on
Unit functions but
lamp does not strike
Lamp is dimmer than
other units
Unit will not home
properly
Color system is not
producing the
correct color
Pan or tilt position is
off
Unit is not responding
to controller
Unit is producing
unexpected results
Display is not func-
tioning
Table A.2: General Troubleshooting
Probable Cause
no power
breaker is turned off
power connectors
power line filter
bad lamp
lamp is too hot from
operation (unit turned
off and on)
ignitor connection is
loose
bad lamp
dirty optics
belt(s) is loose
bad sensor(s)
unit is not homed
properly
unit is not homed
properly
belt tension too loose
wrong fixture DMX
address
bad data cable(s)
link not terminated
incorrect DMX starting
address on the
controller
last fixture is not
terminated
display is turned off
power connectors are
loose
bad logic board
Solution
connect power
turn breaker on
refer to qualified technician
refer to qualified technician
replace lamp
leave the unit turned on, when
the lamp's temperature drops, it
will restrike
refer to qualified technician
replace lamp
dirty optics
tighten belt(s)
refer to qualified technician
home the unit
home the unit
tighten belt(s)
set the address as outlined in
"Address Menu" on page 3-16
check and replace data cables
as needed
terminate link as outlined in
"Data Cabling" on page 1-9
refer to "Setting the Fixture
Address" on page 1-10
terminate fixture
refer to "Setting Display
Intensity" on page 3-27
refer to qualified technician
refer to qualified technician
Appendix A Troubleshooting and Maintenance
2
A-7