Display
Message
flash ROM could
E R S E
not be erased dur-
F L S H
ing an upload
Field Programmable
F P G A
Gate Array error
E R R
ID or unique num-
I d
ber error
E R R
lamp has extin-
L A M P
guished during
O U T
operation
E R R
lamp time-out error
L A M P
T O U T
E R R
other data present
L I N K
on the link during a
b U S Y
crossload
no fixtures were
L I N K
found to crossload
E M T Y
to
link error
L I N K
E R R
logic board is over
O V E R
rated its tempera-
T E M P
ture
A-4
Studio Spot User's Manual
Table A.1: Display Error Messages (Continued)
Problem
•
bad flash ROM
•
read/write error from
FPGA
•
error reading ID
•
error reading unique
fixture number
•
dead lamp
•
lamp too hot to restrike
•
dead lamp
•
ignitor error
•
controller is connected
to the link
•
additional Studio Spot
fixtures are not
connected to the
master during a
crossload
•
bad cable(s)
•
output from previous
fixture is bad
•
bad comm board
•
temperature exceeds
limit for safe operation
and the board has
shutdown
Explanation
Solution
•
refer to qualified
service personnel
•
refer to qualified
service personnel
•
refer to qualified
service personnel
•
replace lamp, refer to
"Replacing the
Lamp" on page A-10
•
allow time for the
lamp to cool and
restrike the lamp
•
replace lamp, refer to
"Replacing the
Lamp" on page A-10
•
refer to qualified
service personnel
•
disconnect
controller
•
connect additional
fixtures
•
check cabling
•
test and replace
cable(s) as necessary
•
test by bypassing
previous fixture
•
refer to qualified
service personnel
•
reduce ambient
temperature and
move significant
heat sources
•
refer to qualified
service personnel