High End Systems studio spot User Manual page 108

Automated projection and effect luminaire
Hide thumbs Also See for studio spot:
Table of Contents

Advertisement

Display
Message
flash ROM could
E R S E
not be erased dur-
F L S H
ing an upload
Field Programmable
F P G A
Gate Array error
E R R
ID or unique num-
I d
ber error
E R R
lamp has extin-
L A M P
guished during
O U T
operation
E R R
lamp time-out error
L A M P
T O U T
E R R
other data present
L I N K
on the link during a
b U S Y
crossload
no fixtures were
L I N K
found to crossload
E M T Y
to
link error
L I N K
E R R
logic board is over
O V E R
rated its tempera-
T E M P
ture
A-4
Studio Spot User's Manual
Table A.1: Display Error Messages (Continued)
Problem
bad flash ROM
read/write error from
FPGA
error reading ID
error reading unique
fixture number
dead lamp
lamp too hot to restrike
dead lamp
ignitor error
controller is connected
to the link
additional Studio Spot
fixtures are not
connected to the
master during a
crossload
bad cable(s)
output from previous
fixture is bad
bad comm board
temperature exceeds
limit for safe operation
and the board has
shutdown
Explanation
Solution
refer to qualified
service personnel
refer to qualified
service personnel
refer to qualified
service personnel
replace lamp, refer to
"Replacing the
Lamp" on page A-10
allow time for the
lamp to cool and
restrike the lamp
replace lamp, refer to
"Replacing the
Lamp" on page A-10
refer to qualified
service personnel
disconnect
controller
connect additional
fixtures
check cabling
test and replace
cable(s) as necessary
test by bypassing
previous fixture
refer to qualified
service personnel
reduce ambient
temperature and
move significant
heat sources
refer to qualified
service personnel