Optimizing the Lamp

When a lamp is replaced, you will need to optimize the new lamp's position in
the optical path. Optimizing the lamp ensures that you will have a flat field
across the entire beam diameter.
To optimize the lamp, you will need the following items:
• #2 phillips screw driver
• smooth white surface to project the beam on
• table or a truss to mount the fixture on
To optimize the lamp, complete the following procedure:
1. Mount the fixture in an orientation so that it may be squarely projected
onto a smooth white surface no less than 10 feet (3 meters) away.
2. Using a controller or the menu system, focus an open (white) beam
onto the surface and observe the beam.
3. Using a #2 phillips-head screw driver, rotate the three lamp adjust
screws until you achieve a uniform flat field. Refer to Figure A.3. When
the lamp is correctly optimized, the field will have an even
disbursement of light throughout the entire beam diameter.
A-12 Studio Spot User's Manual
Lamp Adjust
Lamp Adjust
CAUTION:
Hot lamp. Risk of fire. Use only M
Series GX 9.5 base, 575 watt, metal halide type
,
lamp. To prevent electrical shock, disconnect
from power supply. Allow at least 5 minutes
before removing cover.
ATTENTION:
Lampe brûlante. Risque
d'incendie. Utiliser uniquement une lampe à
halogène-métal de 575 watts, base GX 9.5, série
M. Pour éviter les chocs électriques, débrancher.
A
ttendre au moins 5 minutes avant d'enlever le
couvercle.
WARNING:
Lamp Adjust
Lamps may be an
explosion hazard,
wear eye protection.
99310292 -
Figure A.3. Lamp Optimization Screws