Debugging and Diagnostics Parameters

This subsection describes the device's debugging and diagnostic parameters.

44.3.1 General Parameters

The general debugging and diagnostic parameters are described in the table below.
Table 44-16: General Debugging and Diagnostic Parameters
Parameter
EMS: Enable Diagnostics
[EnableDiagnostics]
Web: Enable LAN Watchdog
[EnableLanWatchDog]
Version 6.6
Note: For this parameter to take effect, a device reset is required.
Defines the RS-232 stop bit.
[1] = (Default) 1-bit (default)
[2] = 2-bit
Note: For this parameter to take effect, a device reset is required.
Defines the RS-232 flow control.
[0] = (Default) None
[1] = Hardware
Note: For this parameter to take effect, a device reset is required.
Determines the method for verifying correct functioning of the
different hardware components on the device. On completion of the
check and if the test fails, the device sends information on the test
results of each hardware component to the Syslog server.
[0] = (Default) Rapid and Enhanced self-test mode.
[1] = Detailed self-test mode (full test of DSPs, PCM, Switch,
LAN, PHY and Flash).
[2] = A quicker version of the Detailed self-test mode (full test of
DSPs, PCM, Switch, LAN, PHY, but partial test of Flash).
Note: For this parameter to take effect, a device reset is required.
Enables the LAN watchdog feature.
[0] Disable (default)
[1] Enable
When LAN watchdog is enabled, the device's overall
communication integrity is checked periodically. If no
communication is detected for about three minutes, the device
performs a self test:
If the self-test succeeds, the problem is a logical link down (i.e.,
Ethernet cable disconnected on the switch side) and the Busy
Out mechanism is activated if enabled (i.e., the parameter
EnableBusyOut is set to 1). Lifeline is activated only if it is
enabled (using the parameter LifeLineType).
If the self-test fails, the device restarts to overcome internal fatal