AudioCodes MP-11x User Manual page 604

Mediapack series analog voip gateways
Hide thumbs Also See for MP-11x:
Table of Contents

Advertisement

Parameter
Web: Disconnect on Broken Connection
EMS: Disconnect Calls on Broken
Connection
[DisconnectOnBrokenConnection]
Web: Broken Connection Timeout
EMS: Broken Connection Event
Timeout
[BrokenConnectionEventTimeout]
Web: Disconnect Call on Silence
Detection
EMS: Disconnect On Detection Of
Silence
[EnableSilenceDisconnect]
Web: Silence Detection Period [sec]
EMS: Silence Detection Time Out
[FarEndDisconnectSilencePeriod]
Web: Silence Detection Method
[FarEndDisconnectSilenceMethod]
User's Manual
Description
Determines whether the device releases the call if RTP
packets are not received within a user-defined timeout.
[0] No
[1] Yes (default)
Notes:
The timeout is configured by the
BrokenConnectionEventTimeout parameter.
This feature is applicable only if the RTP session is
used without Silence Compression. If Silence
Compression is enabled, the device doesn't detect a
broken RTP connection.
During a call, if the source IP address (from where the
RTP packets are received) is changed without notifying
the device, the device filters these RTP packets. To
overcome this, set the DisconnectOnBrokenConnection
parameter to 0; the device doesn't detect RTP packets
arriving from the original source IP address and
switches (after 300 msec) to the RTP packets arriving
from the new source IP address.
This parameter can also be configured in an IP Profile.
Defines the time period (in 100-msec units) after which a
call is disconnected if an RTP packet is not received.
The valid range is from 3 (i.e., 300 msec) to an unlimited
value (e.g., 20 hours). The default is 100 (i.e., 10000 msec
or 10 seconds).
Notes:
This parameter is applicable only if the parameter
DisconnectOnBrokenConnection is set to 1.
Currently, this feature functions only if Silence
Suppression is disabled.
Determines whether calls are disconnected after detection
of silence.
[1] Yes = The device disconnects calls in which silence
occurs (in both call directions) for more than a user-
defined time.
[0] No = (Default) Call is not disconnected when silence
is detected.
The silence duration can be configured by the
FarEndDisconnectSilencePeriod parameter (default 120).
Note: To activate this feature, set the parameters
EnableSilenceCompression and
FarEndDisconnectSilenceMethod to 1.
Defines the duration of the silence period (in seconds) after
which the call is disconnected.
The range is 10 to 28,800 (i.e., 8 hours). The default is 120
seconds.
Note: For this parameter to take effect, a device reset is
required.
Determines the silence detection method.
[0] None = Silence detection option is disabled.
[1] Packets Count = According to packet count.
604
MP-11x & MP-124
Document #: LTRT-65432