Error Abbreviation
AC
AL
AO
AP
AR

39.1.2 Identifying AudioCodes Syslog Messages using Facility Levels

The device's Syslog messages can easily be identified and distinguished from Syslog
messages from other equipment, by setting its Facility level. The Facility levels of the
device's Syslog messages are numerically coded with decimal values. Facility level may
use any of the "local use" facilities (0 through 7), according to RFC 3164. Implementing
Facility levels is useful, for example, if you collect the device's as well as other equipments'
Syslog messages on the same server. Therefore, in addition to filtering Syslog messages
according to IP address, the messages can be filtered according to Facility level.
The Facility level is configured using the SyslogFacility ini file parameter, which provides
the following options:
Numerical Value
16 (default)
17
18
19
20
21
22
23
Syslog messages begin with a less-than ("<") character, followed by a number, which is
followed by a greater-than (">") character. This is optionally followed by a single ASCII
space. The number is known as the Priority and represents both the Facility level and the
Severity level. A Syslog message with Facility level 16 is shown below:
Facility: LOCAL0 - reserved for local use (16)
User's Manual
Invalid Channel ID
Invalid Header Length
Invalid Codec Type
Unknown Aggregation Payload Type
Invalid Routing Flag Received
Table 39-3: Syslog Facility Levels
local use 0 (local0)
local use 1 (local1)
local use 2 (local2)
local use 3 (local3)
local use 4 (local4)
local use 5 (local5)
local use 6 (local6)
local use 7 (local7)