Snmp Alarms In Syslog Messages - AudioCodes MP-11x User Manual

Mediapack series analog voip gateways
Hide thumbs Also See for MP-11x:
Table of Contents

Advertisement

User's Manual

39.1.3 SNMP Alarms in Syslog Messages

SNMP alerts are sent to the Syslog server using the following formats:
Raised Alarms: RAISE-ALARM: <Alarm Name>; Textual Description: <Textual
Description>; Severity <Alarm Severity>; Source <Alarm Source>; Unique ID: <Alarm
Unique ID >.
If additional information exists in the alarm, then these are also added: Additional
Info1:/ Additional Info2:/ Additional Info3
The Messages' Severity is as follows:
ITU Perceived Severity
(SNMP Alarm's Severity)
Critical
Major
Minor
Warning
Indeterminate
Cleared
Cleared Alarms: CLEAR-ALARM: <Alarm Name>; Textual Description: <Textual
Description>; Severity <Alarm Severity>; Source <Alarm Source>; Unique ID: <Alarm
Unique ID >; If exists Additional Info1:/ Additional Info2:/ Additional Info3:
Version 6.6
Table 39-4: Syslog Message Severity
RecoverableMsg
RecoverableMsg
RecoverableMsg
Notice
Notice
Notice
447
39. Syslog and Debug Recordings
AudioCodes' Syslog Severity
MP-11x & MP-124

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mediapack mp-124

Table of Contents