To configure Proxy Sets:
1.
Open the Proxy Sets Table page (Configuration tab > VoIP menu > Control
Network submenu > Proxy Sets Table).
2.
From the 'Proxy Set ID' drop-down list, select an ID for the desired group.
3.
Configure the Proxy parameters, as required. For a description of the parameters, see
the table below.
4.
Click Submit.
5.
To save the changes to flash memory, see 'Saving Configuration' on page 366.
Parameter
Web: Proxy Set ID
EMS: Index
[ProxySet_Index]
Version 6.6
Figure 17-1: Proxy Sets Table Page
Table 17-2: Proxy Sets Table Parameters
Defines the Proxy Set identification number.
The valid value is 0 to 9. Proxy Set ID 0 is used as the default Proxy Set.
Note: Although not recommended, you can use both default Proxy Set
(ID 0) and IP Groups for call routing. For example, in the Hunt Group
Settings page (see Configuring Hunt Group Settings on page 237) you
can configure a Serving IP Group to where you want to route specific
Hunt Group endpoints, and all other device endpoints then use the default
Proxy Set. You can also use IP Groups in the Tel to IP Routing (see
Configuring the Tel to IP Routing on page 256) to configure the default
Proxy Set if the parameter PreferRouteTable is set to 1.
To summarize, if the default Proxy Set is used, the INVITE message is
sent according to the following preferences:
To the Hunt Group's Serving IP Group ID, as defined in the Hunt
209