12.3.3 Troubleshooting the Routing Table

When adding a new static routing rule, the added rule passes a validation test. If errors are
found, the routing rule is rejected and is not added to the IP Routing table. Failed routing
validations may result in limited connectivity (or no connectivity) to the destinations
specified in the incorrect routing rule. For any error found in the Routing table or failure to
configure a routing rule, the device sends a notification message to the Syslog server
reporting the problem.
Common routing rule configuration errors may include the following:
The IP address specified in the 'Gateway IP Address' field is unreachable from the
interface specified in the 'Interface Name' field.
The same destination is configured in two different routing rules.
More than 30 routing rules have been configured.
Note:
If an IP routing rule is required to access OAMP applications (for remote
management, for example) and the route is not configured correctly, the route is not
added and the device is not accessible remotely. To restore connectivity, the device
must be accessed locally from the OAMP subnet and the required routes be
configured.
User's Manual
138
MP-11x & MP-124
Document #: LTRT-65432