Parameter
EMS: Baud Rate
[SerialBaudRate]
EMS: Data
[SerialData]
EMS: Parity
[SerialParity]
EMS: Stop
[SerialStop]
EMS: Flow Control
[SerialFlowControl]
51.3

Debugging and Diagnostics Parameters

This subsection describes the device's debugging and diagnostic parameters.
51.3.1 General Parameters
The general debugging and diagnostic parameters are described in the table below.
Table ‎ 5 1-15: General Debugging and Diagnostic Parameters
Parameter
EMS: Enable Diagnostics
[EnableDiagnostics]
Version 6.6
[1] = (Default) Disabled
The RS-232 serial port can be used to change the networking
parameters and view error/notification messages. For how to establish a
serial communication with the device, refer to the Installation Manual.
Note: For this parameter to take effect, a device reset is required.
Defines the RS-232 baud rate.
The valid values include the following: 1200, 2400, 9600, 14400, 19200,
38400, 57600, or 115200 (default).
Note: For this parameter to take effect, a device reset is required.
Defines the RS-232 data bit.
[7] = 7-bit
[8] = (Default) 8-bit
Note: For this parameter to take effect, a device reset is required.
Defines the RS-232 polarity.
[0] = (Default) None
[1] = Odd
[2] = Even
Note: For this parameter to take effect, a device reset is required.
Defines the RS-232 stop bit.
[1] = (Default) 1-bit (default)
[2] = 2-bit
Note: For this parameter to take effect, a device reset is required.
Defines the RS-232 flow control.
[0] = (Default) None
[1] = Hardware
Note: For this parameter to take effect, a device reset is required.
Determines the method for verifying correct functioning of the
different hardware components on the device. On completion of the
check and if the test fails, the device sends information on the test
results of each hardware component to the Syslog server.
[0] = (Default) Rapid and Enhanced self-test mode.
[1] = Detailed self-test mode (full test of DSPs, PCM, Switch,
LAN, PHY and Flash).