Table 59: Sip Peer Trunk Configuration Parameters - Grandstream Networks UCM6510 User Manual

Ip pbx
Hide thumbs Also See for UCM6510:
Table of Contents

Advertisement

CC Max Monitors
Basic Settings
Provider Name
Host Name
Transport
Keep Original CID
Keep Trunk CID
NAT
Disable This Trunk
TEL URI
Configure the maximum number of monitor structures which may be
created for this device. In other words, this number tells how many callers
may request CC services for a specific device at one time. The minimum
value is 1.

Table 59: SIP Peer Trunk Configuration Parameters

Configure a unique label to identify this trunk when listed in outbound rules,
inbound rules and etc.
Configure the IP address or URL for the VoIP provider's server of the trunk.
Configure the SIP transport protocol to be used in this trunk. The default
setting is "All - UDP Primary".
UDP Only
TCP Only
TLS Only
All - UDP Primary: UDP is the primary transport protocol when all the
other SIP transport methods are available too.
All - TCP Primary: TCP is the primary transport protocol when all the
other SIP transport methods are available too.
All – TLS Primary: TLS is the primary transport protocol when all the
other SIP transport methods are available too.
Keep the CID from the inbound call when dialing out, this setting will
override "Keep Trunk CID" option. Please make sure that the peer PBX at
the other side supports to match user entry using "username" field from
authentication line.
If enabled, the trunk CID will not be overridden by extension's CID when
the extension has CID configured. The default setting is "No".
Turn on this option when the PBX is using public IP and communicating
with devices behind NAT. If there is one-way audio issue, usually it's
related to NAT configuration or SIP/RTP port configuration on the firewall.
If selected, the trunk will be disabled.
Note:
If a current SIP trunk is disabled, UCM6510 will send UNREGISTER
message (REGISTER message with expires=0) to the SIP provider.
If the trunk has an assigned PSTN telephone number, this field should be
set to "User=Phone". Then a "User=Phone" parameter will be attached to
the Request-Line and TO header in the SIP request to indicate the E.164
number. If set to "Enable", "Tel:" will be used instead of "SIP:" in the SIP
request. The default setting is disabled.
UCM6510 IP PBX User Manual
P a g e
|
184

Advertisement

Table of Contents
loading