Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
– If drive was intentionally removed, no action required.
– Make sure that the drive properly seated.
– If drive is properly seated, replace the drive.
816f000f-2201xxxx : The System [ComputerSystemElementName] has detected a POST Error
deassertion.
IMM has detected that Post Error has deasserted. (ABR Status or Firmware Error).
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0185
User Response
This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of
the Info Center for the appropriate user response.
816f000f-2202xxxx : The System [ComputerSystemElementName] has detected a POST Error
deassertion.
This message is for the use case when an implementation has detected that Post Error has deasserted.
Severity
Info
Appendix D. Integrated management module II (IMM2) error messages