User Response
– Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing
drive(s).
– Replace the hard disk drives that are indicated by a lit status LED.
– Recreate the array.
– Restore data from backup.
• 806f060d-0418xxxx : Array [ComputerSystemElementName] has failed.
The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all
member drives will report this message.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
– Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing
drive(s).
– Replace the hard disk drives that are indicated by a lit status LED.
– Recreate the array.
– Restore data from backup.
• 806f060d-0419xxxx : Array [ComputerSystemElementName] has failed.
The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all
member drives will report this message.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5