Information only; no action is required.
806f011b-0701xxxx : The connector [PhysicalConnectorElementName] has encountered a
configuration error.
IMM has detected Interconnect Configuration Error.
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0266
User Response
FPGA Comm Err:
1. AC cycle the machine.
2. Update IMM FW to the latest level.
3. (Trained service technician only) If error persists, replace system board.
USB Detect:
1. Reinsert the USB/Video cable.
2. Replace the USB/Video cable.
806f0123-2101xxxx : Reboot of system [ComputerSystemElementName] initiated by
[WatchdogElementName].
The IPMI Watchdog Timer has expired. A reboot of the system was initiated.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other