2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers
are in place and correctly installed.
3. Ensure system cover is latched properly.
4. Make sure that the room temperature is within operating specifications.
80010701-1403xxxx : Numeric sensor [NumericSensorElementName] going high (upper
non-critical) has asserted.
IMM has detected that the temperature of a system board voltage regulator has risen above normal levels.
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0490
User Response
1. Check event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers
are in place and correctly installed.
3. Ensure system cover is latched properly.
4. Make sure that the room temperature is within operating specifications.
80010701-1404xxxx : Numeric sensor [NumericSensorElementName] going high (upper
non-critical) has asserted.
IMM has detected that the temperature of a system board voltage regulator has risen above normal levels.
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12