User Response
Check the IMM event log for any fan, cooling, or power related issues.
For a thermal condition:
1. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers
are in place and correctly installed.
2. Make sure that the room temperature is within operating specifications.
For a power condition:
1. If Power Supply Unit is rated 1400 Watt, Make sure it is connected to 220V AC input
2. If using a 900 Watt rated power supply (connected at either 110V or 220 V ), may need to
upgrade to a 1400 Watt rated power supply (connected at 220V).
806f0a0c-2581xxxx : An Over-Temperature Condition has been detected on the
[PhysicalMemoryElementName] on Subsystem [MemoryElementName].
IMM has detected an over temperature condition on the memory.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0146
User Response
Complete the following steps:
1. Check the IMM event log for any fan, cooling, or power related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers
are in place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
• 806f0a13-0301xxxx : A Fatal Bus Error has occurred on bus [SensorElementName].
776