Lenovo System x3750 M4 Installation And Service Manual page 610

Hide thumbs Also See for System x3750 M4:
Table of Contents

Advertisement

• 80070219-0701xxxx : Sensor [SensorElementName] has transitioned to critical from a less severe
state.
IMM has detected a System Board Fault Sensor has transitioned to critical.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0522
User Response
This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of
the Info Center for the appropriate user response.
• 8007021b-0301xxxx : Sensor [SensorElementName] has transitioned to critical from a less severe
state.
IMM has detected a CPU 1 QPI Link Error.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0522
User Response
This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of
the Info Center for the appropriate user response.
• 8007021b-0302xxxx : Sensor [SensorElementName] has transitioned to critical from a less severe
state.
596
Lenovo System x3750 M4 Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents