Lenovo System x3750 M4 Installation And Service Manual page 711

Hide thumbs Also See for System x3750 M4:
Table of Contents

Advertisement

CIM Information
Prefix: PLAT ID: 0144
User Response
This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of
the Info Center for the appropriate user response.
• 806f050d-0400xxxx : Array [ComputerSystemElementName] is in critical condition.
The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a
system outage. To identify drives in the critical array all member drives will report this message.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0174
User Response
– Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing
drive(s).
– Replace the hard disk drive that is indicated by a lit status LED.
• 806f050d-0401xxxx : Array [ComputerSystemElementName] is in critical condition.
The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a
system outage. To identify drives in the critical array all member drives will report this message.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0174
Appendix D. Integrated management module II (IMM2) error messages
697

Advertisement

Table of Contents
loading

Table of Contents