2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers
are in place and correctly installed.
3. Ensure system cover is latched properly.
4. Make sure that the room temperature is within operating specifications.
5. (Trained service technician only) Replace ML2 Card.
80070319-2201xxxx : Sensor [SensorElementName] has transitioned to non-recoverable from
a less severe state.
IMM has detected system failed to resume from S3 power state.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0524
User Response
This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of
the Information Center for the appropriate user response.
• 80070603-0701xxxx : Sensor [SensorElementName] has transitioned to non-recoverable.
IMM has detected Voltage Regulator Error.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0530
User Response
604