• 80070603-0b01xxxx : Sensor [SensorElementName] has transitioned to non-recoverable.
IMM has detected Voltage Regulator Error.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0530
User Response
ML2 card VRD: Indicates a problem with either the voltage regulator for the ML2 card or the ML2
card itself
1. Check the IMM Web event log. This event may be a symptom of an earlier error.
2. Replace the ML2 Ethernet Adapter if installed.
3. Replace the system board.
• 80070603-2584xxxx : Sensor [SensorElementName] has transitioned to non-recoverable.
IMM has detected Voltage Regulator Error.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0530
User Response
Power Supply: Indicates a problem with either the system board voltage or the power supply is failing