– Replace the hard disk drive that is indicated by a lit status LED.
• 806f050d-0406xxxx : Array [ComputerSystemElementName] is in critical condition.
The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a
system outage. To identify drives in the critical array all member drives will report this message.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0174
User Response
– Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing
drive(s).
– Replace the hard disk drive that is indicated by a lit status LED.
• 806f050d-0407xxxx : Array [ComputerSystemElementName] is in critical condition.
The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a
system outage. To identify drives in the critical array all member drives will report this message.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0174
User Response
– Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing
drive(s).
– Replace the hard disk drive that is indicated by a lit status LED.