IMM has detected that System Firmware Error No video device detected has occurred.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0766
User Response
This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of
the Info Center for the appropriate user response.
806f000f-22020bxx : Firmware BIOS (ROM) corruption was detected on system
[ComputerSystemElementName] during POST.
Firmware BIOS (ROM) corruption was detected on the system during POST.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0850
User Response
This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of
the Info Center for the appropriate user response.
• 806f000f-22020cxx : CPU voltage mismatch detected on [ProcessorElementName].
IMM has detected a CPU voltage mismatch with the socket voltage.