1. Power Unit: Check if Power Supply is missing, unplugged.
2. Check the power supply LEDs, see "Power-supply LEDs"
3. Replace the affected power supply.
• 800b0309-0a01xxxx : Non-redundant:Sufficient Resources from Redundancy Degraded or Fully
Redundant for [RedundancySetElementName] has asserted.
Power Supply is supplying sufficient power but is no longer in a redundancy state.
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Redundant Power Supply
SNMP Trap ID
10
CIM Information
Prefix: PLAT ID: 0806
User Response
1. Power Unit: Check if Power Supply is missing, unplugged.
2. Check the power supply LEDs, see "Power-supply LEDs"
3. Replace the affected power supply.
• 800b030c-2581xxxx : Non-redundant:Sufficient Resources from Redundancy Degraded or Fully
Redundant for [RedundancySetElementName] has asserted.
Backup Memory has transitioned from Redundancy Degraded or Fully Redundant to
Non-redundant:Sufficient.
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43