Lenovo System x3750 M4 Installation And Service Manual page 152

Hide thumbs Also See for System x3750 M4:
Table of Contents

Advertisement

– TPM Device State
Select this choice to display the current state of the TPM device.
– TPM TXT Status
Select this choice to display the current state of Trusted Execution Technology (TXT).
– MOR Status
Select this choice to display the current state of the Memory Overwrite Request (MOR).
– Refresh TPM Status
Select this choice to get the current status of the TPM chip.
– TPM Device
Select this choice to enable or disable the TPM device. This command requires the TPM physical
presence to be in the asserted state. A reboot of the server is required to successfully enable
or disable the TPM device.
– TPM State
Select this choice to activate or deactivate the TPM device. This command requires the TPM
physical presence to be in the asserted state. A reboot of the server is required to successfully
activate or deactivate the TPM device.
– TXT State
Make sure the TPM is enabled and activated prior to enabling the TXT feature. A reboot of the server
is required to successfully perform this command.
– MOR State
Select this choice to enable or disable the MOR feature.
– TPM Force Clear
Select this choice to erase the contents of the TPM. This command requires the TPM physical
presence to be in the asserted state. A reboot of the server is required to successfully perform
this command.
– Integrated Management Module
Select this choice to view or change the settings for the integrated management module II (IMM2).
– Power Restore Policy
Select this choice to determine the mode of operation to which the server will be restored after a
power outage occurs. To restore the server to the state it was set to at the time of the power outage,
select one of the following choices:
• Always Off
After the power is restored the server remains in the off mode of operation.
• Restore
After the power is restored, the server returns to the mode of operation prior to the power failure.
• Always On
After the power is restored, the server returns to the on mode of operation. Allow a few minutes
for any changes to take effect.
– Commands on USB Interface Preference
Select this choice to enable or disable the Ethernet over USB interface on the IMM2. Allow a few
minutes for any changes to take effect.
– Network Configuration
Select this choice to perform the following activities:
138
Lenovo System x3750 M4 Installation and Service Guide