Prefix: PLAT ID: 0126
User Response
This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of
the Info Center for the appropriate user response.
806f070c-2581xxxx : Configuration Error for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName].
IMM has detected that a Memory DIMM configuration error has occurred.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0126
User Response
This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of
the Info Center for the appropriate user response.
• 806f070d-0400xxxx : Rebuild in progress for Array in system [ComputerSystemElementName].
IMM has detected that an Array Rebuild is in Progress.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0178
User Response
Information only; no action is required.
Appendix D. Integrated management module II (IMM2) error messages