Lenovo System x3750 M4 Installation And Service Manual page 373

Hide thumbs Also See for System x3750 M4:
Table of Contents

Advertisement

407-800-000 : LSIESG:DiskDefaultDiagnostic Test Aborted
The test was canceled.
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
IBM Support website
Latest level of DSA
Latest level of BMC/IMM
407-900-000 : LSIESG:DiskDefaultDiagnostic Test Failed
The hard drive self-test detected a failure.
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check cable connections.
2. Rerun the test.
3. Verify whether the firmware is at the latest level.
4. Rerun the test.
5. If the problem remains, contact your IBM technical-support representative.
Related links
IBM Support website
Latest level of DSA
Latest level of BMC/IMM
Appendix B. DSA diagnostic test results
359

Advertisement

Table of Contents
loading

Table of Contents