• 80010901-1402xxxx : Numeric sensor [NumericSensorElementName] going high (upper critical)
has asserted.
IMM has detected that the temperature of a system board voltage regulator has risen above the upper
critical threshold.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0494
User Response
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers
are in place and correctly installed.
3. Ensure system cover is latched properly.
4. Make sure that the room temperature is within operating specifications.
• 80010901-1403xxxx : Numeric sensor [NumericSensorElementName] going high (upper critical)
has asserted.
IMM has detected that the temperature of a system board voltage regulator has risen above the upper
critical threshold.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0494
User Response
1. Check the IMM event log for any fan or cooling related issues.
Appendix D. Integrated management module II (IMM2) error messages