201-813-000 : Standalone Memory Test Aborted
Chipset Error: Can not turn OFF ECC error reporting in CPU.
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
IBM Support website
Latest level of DSA
Latest level of BMC/IMM
201-813-001 : Standalone Memory Test Aborted
Chipset Error: Can not turn OFF ECC error reporting in CPU.
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.