• 80070608-2584xxxx : Sensor [SensorElementName] has transitioned to non-recoverable.
IMM has detected Power Supply related fault. (PS 12V OC Fault, PS 12V OV Fault, PS 12V UV Fault, or
PS AUX UV Fault)
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0530
User Response
1. Check the power supply LEDs, see "Power-supply LEDs".
2. Replace the failing power supply.
• 8007060f-2201xxxx : Sensor [SensorElementName] has transitioned to non-recoverable.
Trusted Platform Module (TPM) initialization error.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0530
User Response
This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of
the Info Center for the appropriate user response.
8008000f-2101xxxx : Device [LogicalDeviceElementName] has been removed from unit
[PhysicalPackageElementName].