Lenovo System x3750 M4 Installation And Service Manual page 630

Hide thumbs Also See for System x3750 M4:
Table of Contents

Advertisement

CIM Information
Prefix: PLAT ID: 0810
User Response
1. Power Unit: Check if Power Supply is missing, unplugged.
2. Check the power supply LEDs, see "Power-supply LEDs"
3. Replace the affected power supply.
4. Check the power supply max rate and power capping policy, if the required power resource is
not met, change the power supply or modify power capping mechanism.
• 800b050a-1e81xxxx : Non-redundant:Insufficient Resources for [RedundancySetElementName]
has asserted.
Insufficient cooling provided by fan 1.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0810
User Response
Replace Fan 1
• 800b050a-1e82xxxx : Non-redundant:Insufficient Resources for [RedundancySetElementName]
has asserted.
Insufficient cooling provided by fan 2.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
616
Lenovo System x3750 M4 Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents