Setting 8: Conveyor Application 2 - YASKAWA CIMR-VU BA0001 Technical Manual

Ac drive-v1000 200 v class, three-phase input: 0.1 to 18.5 kw; 200 v class, single-phase input: 0.1 to 3.7 kw; 400 v class, three-phase input: 0.2 to 18.5 kw
Table of Contents

Advertisement

No.
L8-07
Output Phase Loss Protection Selection
L8-38
Carrier Frequency Reduction
L8-41
High Current Alarm Selection
<1> Disable L8-05 for single-phase models.
No.
b1-01
Frequency Reference Selection 1
C1-01
Acceleration Time 1
C1-02
Deceleration Time 1
C6-02
Carrier Frequency Selection
d1-01
Frequency Reference 1
d1-02
Frequency Reference 2
u

Setting 8: Conveyor Application 2

This setting is available in drive software versions PRG: 1020 and later.
No.
A1-02
Control Method Selection
C1-01
Acceleration Time 1
C1-02
Deceleration Time 1
C6-01
Drive Duty Selection
L3-04
Stall Prevention Selection during Deceleration
n3-13
Overexcitation Deceleration Gain
n3-21
High-Slip Suppression Current Level
No.
A1-02
Control Method Selection
b1-01
Frequency Reference Selection 1
b1-02
Run Command Selection 1
C1-01
Acceleration Time 1
C1-02
Deceleration Time 1
YASKAWA ELECTRIC SIEP C710606 18F YASKAWA AC Drive – V1000 Technical Manual
Parameter Name
Table 4.18 Preset 7: User Parameters (A2-01 to A2-16):
Parameter Name
Table 4.19 Conveyor 2: Parameters and Settings
Parameter Name
Table 4.20 Conveyor 2: User Parameters (A2-01 to A2-16):
Parameter Name
Default Setting
1: Triggered when a single phase is lost
1: Enabled below 6 Hz
1: Enabled (alarm output)
No.
Parameter Name
d1-03
Frequency Reference 3
E2-01
Motor Rated Current
H1-05
Multi-Function Digital Input Terminal S5 Function
H1-06
Multi-Function Digital Input Terminal S6 Function
H2-01
Terminals MA, MB, and MC Function Selection
L1-01
Motor Overload Protection Selection
Default Setting
0: V/f Control
3.0 s
3.0 s
0: Heavy Duty
0: Disabled
1.4
150%
No.
Parameter Name
E2-01
Motor Rated Current
L3-04
Stall Prevention Selection during Deceleration
n3-13
Overexcitation Deceleration Gain
n3-21
High-Slip Suppression Current Level