7.4 Drive Cooling Fans
n
Installing the Cooling Fan
NOTICE: Prevent Equipment Damage. Follow cooling fan replacement instructions. Improper cooling fan replacement could result in
damage to equipment. When installing the replacement cooling fan into the drive, make sure the fan is facing upwards. To ensure maximum
useful product life, replace all cooling fans when performing maintenance.
1.
Install the replacement cooling fan into the drive, ensuring the alignment pins line up, as shown in the figure below:
A – Label facing up
B – Back
2.
Ensure the connectors are properly connected and place the cable back into the recess of the drive.
A –Push the connectors together so no space remains between them.
Note:
Ensure that the left and right tabs are locked back into place.
3.
Align the left and right cover tabs to install the fan cover back on the top of the drive.
318
A
C – Front
Figure 7.3 Cooling Fan Orientation
A
Figure 7.4 Connectors
YASKAWA ELECTRIC SIEP C710606 18F YASKAWA AC Drive – V1000 Technical Manual
B
C