YASKAWA CIMR-VU BA0001 Technical Manual page 363

Ac drive-v1000 200 v class, three-phase input: 0.1 to 18.5 kw; 200 v class, single-phase input: 0.1 to 3.7 kw; 400 v class, three-phase input: 0.2 to 18.5 kw
Table of Contents

Advertisement

No.
Name
C4-01
Torque Compensation Gain
<5>
Torque Compensation
C4-02
Primary Delay Time
Torque Compensation at
C4-03
Forward Start
Torque Compensation at
C4-04
Reverse Start
Torque Compensation Time
C4-05
Constant
Torque Compensation
C4-06
Primary Delay Time 2
C5 parameters are available only when using V/f Control with Simple PG Feedback (H6-01 = 3).
C5-01
ASR Proportional Gain 1
<1>
C5-02
ASR Integral Time 1
<1>
C5-03
ASR Proportional Gain 2
<1>
C5-04
ASR Integral Time 2
<1>
C5-05
ASR Limit
<1>
C6-01
Drive Duty Selection
C6-02
Carrier Frequency Selection
YASKAWA ELECTRIC SIEP C710606 18F YASKAWA AC Drive – V1000 Technical Manual
Description
V/f Control: Sets the gain for the automatic torque (voltage)
boost function and helps to produce better starting torque.
Increase this setting when using a long motor cable or when
the motor is significantly smaller than the drive capacity.
Decrease this setting when motor oscillation occurs. Set the
value so that the current at low speed does not exceeds the
drives rated current.
Open Loop Vector: Sets the torque compensation function
gain. Normally no change is required.
Sets the torque compensation filter time.
Increase this setting when motor oscillation occurs.
Reduce the setting if there is not enough response from the
motor.
Sets torque compensation at forward start as a percentage
of motor torque.
Sets torque compensation at reverse start as a percentage of
motor torque.
Sets the time constant for torque compensation at forward
start and reverse start (C4-03 and C4-04). The filter is
disabled if the time is set to 4 ms or less.
Sets the torque compensation time 2. When an ov fault
occurs with sudden load changes or at the and of an
acceleration, increase the setting.
Note: Adjustment is not normally required. If adjusted then
AFR time 2 (n2-03) should be adjusted too.
C5: Speed Control (ASR)
Use C5 parameters to configure the Automatic Speed Regulator (ASR).
Sets the proportional gain of the speed control loop (ASR).
Sets the integral time of the speed control loop (ASR).
Sets the speed control gain 2 of the speed control loop
(ASR).
Sets the integral time 2 of the speed control loop (ASR).
Sets the upper limit for the speed control loop (ASR) as a
percentage of the maximum output frequency (E1-04).
C6: Carrier Frequency
Use C6 parameters to configure the carrier frequency drive settings.
Selects the load rating for the drive.
0: Heavy Duty (HD) for constant torque applications.
1: Normal Duty (ND) for variable torque applications.
This setting affects the Rated output current and overload
tolerance of the drive.
Selects the carrier frequency
1 : 2.0 kHz
2 : 5.0 kHz
3 : 8.0 kHz
4 : 10.0 kHz
5 : 12.5 kHz
6 : 15.0 kHz
7 : Swing PWM1 (Audible sound 1)
8 : Swing PWM2 (Audible sound 2)
9 : Swing PWM3 (Audible sound 3)
A : Swing PWM4 (Audible sound 4)
B: Leakage Current Rejection PWM
C to E: No setting possible
F : User defined (determined by C6-03 through C6-05)
Range
0.00 to 2.50
0 to 60000 200 ms
0.0 to 200.0 0.0%
-200.0 to
0.0
0 to 200
0 to 10000 150 ms –
0.00 to
300.00
0.000 to
10.000
0.00 to
300.00
0.000 to
10.000
0.0 to 20.0
0, 1
<7>
<3>
B.2 Parameter Table
Control
Mode
Addr.
Def.
Pg.
O
Hex
V/
P
L
f
M
V
1.00
A A A
215
152
<4>
A A A
216
153
<6>
A
217
153
0.0%
A
218
153
10 ms
A
219
153
A
21AH
153
0.20
A
21B
155
0.200
A
21C
155
0.02
A
21D
155
0.050 s A
21E
155
5.0%
A
21F
155
1
S
S
S
223
155
<8>
S
S
S
224
156
B
363