YASKAWA CIMR-VU BA0001 Technical Manual page 246

Ac drive-v1000 200 v class, three-phase input: 0.1 to 18.5 kw; 200 v class, single-phase input: 0.1 to 3.7 kw; 400 v class, three-phase input: 0.2 to 18.5 kw
Table of Contents

Advertisement

5.9 n: Special Adjustments
n
n8-91: Id Limit for Output Voltage Limit Control
Note:
Parameter available in drive software versions PRG: 1018 and later.
Sets the amount of pull-in current that flows through the motor while operating at constant speed. Set as a percentage of the
motor rated current (E5-03). Increase this setting if hunting occurs at constant speed.
No.
Name
Setting Range
Default
n8-91
Id Limit for Output Voltage Limit Control
-200 to 0%
-50%
246