YASKAWA CIMR-VU BA0001 Technical Manual page 453

Ac drive-v1000 200 v class, three-phase input: 0.1 to 18.5 kw; 200 v class, single-phase input: 0.1 to 3.7 kw; 400 v class, three-phase input: 0.2 to 18.5 kw
Table of Contents

Advertisement

Register No.
Fault contents 3
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
00C0H
bit 7
bit 8
bit 9
bit A
bit B
bit C
bit D
bit E
bit F
Fault contents 4
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5 to 6
bit 7
00C1H
bit 8
bit 9
bit A
bit B
bit C
bit D
bit E
bit F
Fault contents 5
bit 0
bit 1
bit 2 to 3
bit 4
bit 5
00C2H
bit 6
bit 7
bit 8
bit 9
bit A
bit B to E
bit F
YASKAWA ELECTRIC SIEP C710606 18F YASKAWA AC Drive – V1000 Technical Manual
Contents
Reserved
Undervoltage (Uv1)
Control Power Supply Undervoltage (Uv2)
Soft Charge Circuit Fault (Uv3)
IGBT Short Circuit or Ground Fault (SC)
Ground Fault (GF)
Overcurrent (oC)
Overvoltage (ov)
Heatsink Overheat (oH)
Heatsink Overheat (oH1)
Motor Overload (oL1)
Drive Overload (oL2)
Overtorque Detection 1 (oL3)
Overtorque Detection 2 (oL4)
Dynamic Braking Transistor Fault (rr)
Braking Resistor Overheat (rH)
External Fault at input terminal S3 (EF3)
External Fault at input terminal S4 (EF4)
External Fault at input terminal S5 (EF5)
External Fault at input terminal S6 (EF6)
External Fault at input terminal S7 (EF7)
Reserved
Overspeed (oS)
Excessive Speed Deviation (dEv)
PG Disconnected (PGo)
Input Phase Loss (PF)
Output Phase Loss (LF)
Motor Overheat Alarm (PTC input) (oH3)
Digital Operator Connection Fault (oPr)
EEPROM Write Error (Err)
Motor Overheat Fault (PTC input) (oH4)
MEMOBUS/Modbus Communication Error (CE)
Option Communication Error (bUS)
Reserved
Control Fault (CF)
Reserved
Option External Fault (EF0)
PID Feedback Loss (FbL)
Undertorque Detection 1 (UL3)
Undertorque Detection 2 (UL4)
High Slip Braking Overload (oL7)
Reserved
Hardware fault (includes oFAoo)
C.10 MEMOBUS/Modbus Data Table
C
453

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents