YASKAWA CIMR-VU BA0001 Technical Manual page 387

Ac drive-v1000 200 v class, three-phase input: 0.1 to 18.5 kw; 200 v class, single-phase input: 0.1 to 3.7 kw; 400 v class, three-phase input: 0.2 to 18.5 kw
Table of Contents

Advertisement

No.
Name
Automatic Reduction
L3-23
Selection for Stall Prevention
during Run
Motor Acceleration Time for
L3-24
Inertia Calculations
L3-25
Load Inertia Ratio
Speed Agreement Detection
L4-01
Level
Speed Agreement Detection
L4-02
Width
Speed Agreement Detection
L4-03
Level (+/-)
Speed Agreement Detection
L4-04
Width (+/-)
Frequency Reference Loss
L4-05
Detection Selection
Frequency Reference at
L4-06
Reference Loss
Frequency Detection
L4-07
Conditions
L4-08
Speed Agreement Detection
<12>
Conditions
Number of Auto Restart
L5-01
Attempts
Auto Restart Operation
L5-02
Selection
L5-04
Fault Reset Interval Time
Fault Reset Operation
L5-05
Selection
YASKAWA ELECTRIC SIEP C710606 18F YASKAWA AC Drive – V1000 Technical Manual
Description
0: Sets the Stall Prevention level throughout the entire
frequency range to the value in parameter L3-06.
1: Automatically lowers the Stall Prevention level in the
constant output range. The lower limit value is 40% of L3-06.
Sets the time needed to accelerate the uncoupled motor at rated
torque from stop to the maximum frequency.
Setting the drive capacity to parameter o2-04 or changing
E2-11 will automatically set this parameter for a 4-pole motor.
Sets the ratio between the motor and machine inertia.
L4: Frequency Detection
Use L4 parameters to configure frequency detection operation.
These parameters configure the multi-function output (H2-
oo = 2, 3, 4, 5) settings "Speed Agree 1", "User Set Speed
Agree 1", "Frequency Detection 1," and "Frequency detection
2".
Parameter L4-01 sets the level while parameter L4-02 sets the
hysteresis for the Speed Detection Output Function.
These parameters configure the Multi-Function Output (H2-
oo = 13, 14, 15, 16) settings "Speed Agree 2", "User Set
Speed Agree 2", "Frequency Detection 3," or "Frequency
Detection 4".
Parameter L4-03 sets the level while parameter L4-04 sets the
hysteresis for the Speed Detection Output Function.
Sets operation when the frequency reference is lost (reference
drops 90% or more within 400 ms).
0: Stop - Drive will stop.
1: Run at L4-06 Level - Drive will run at the percentage set in
L4-06 of the frequency reference before loss.
Sets the frequency reference when a reference loss was
detected and L4-05 = 1. Reference will be: Fref = Fref at time
of loss x L4-06.
0: No detection during baseblock.
1: Detection always enabled.
0: Match speed with the soft-starter output
1: Match frequency reference and motor speed
Note: In V/f Control, the drive ignores the value set to L4-08
and refers to the soft-starter output to determine whether a
speed agree situation has been reached.
L5: Fault Reset
Use L5 parameters to configure Automatic Restart after fault.
Sets the counter for the number of times the drive attempts to
restart when one of the following faults occurs: GF, LF, oC,
oH1, ov, PF, rH, rr, oL1, oL2, oL3, oL4, STo, Uv1.
Parameter L5-05 determines the how the restart counter is
incremented.
When the drive operates without fault for 10 minutes, the
counter will be reset.
Sets fault contact (H2-oo = E) activation during automatic
restart attempts.
0: Fault output not active.
1: Fault output active during restart attempt.
Sets the amount of time to wait between performing fault
restarts. Enabled when L5-05 is set to 1.
Selects the method of incrementing the restart counter.
0: Continuously attempt to restart and increment counter after
successful restart (same as Varispeed VS616-F7/G7)
1: Attempt to restart with the interval time set in L5-04. Every
trial increments the counter. (same as Varispeed VS606-V7)
L6: Overtorque Detection
Use L6 parameters to configure overtorque detection.
B.2 Parameter Table
Control
Mode
Range
Def.
O
V/
P
L
f
M
V
0, 1
0
A A Α
<4>
0.001 to
<10>
A A A
10.000
<11>
0.0 to
1.0
A A A
1000.0
0.0 to
0.0 Hz A A A
400.0
0.0 to 20.0 2.0 Hz A A A
-400.0 to
0.0 Hz A A A
+400.0
0.0 to 20.0 2.0 Hz A A A
0, 1
0
A A A
0.0 to
80.0% A A A
100.0
0, 1
0
A A A
0, 1
0
A A A
0 to 10
0
A A A
0, 1
0
A A A
0.5 to
10.0 s A A A
600.0 s
0, 1
0
A A A
Addr.
Pg.
Hex
4FD
225
46E
226
46F
227
499
227
49A
227
49B
227
49C
227
49D
227
4C2
228
470
228
47F
228
49E
230
49F
230
46C
231
B
467
231
387